-40%

Industrial Grade Single-phase Solid State Relays Module DC-AC SSR-100DA~ 500DA

$ 10.13

Availability: 31 in stock
  • Brand: Unbranded
  • Model: Single phase solid state relay
  • Country/Region of Manufacture: China
  • Current Type: AC/DC
  • Suitable For: Ceiling, Exterior, Interior, Wall
  • Number of Phases: 1
  • Condition: New
  • Application: Industrial, Cooker, Branch Circuit, Control Equipment Panels, Conveyance Lines, Electrical Wiring, Electronics, Fan Control, Instruments, Large Appliances, Light Control, Marine, Recreational Vehicle (RV), Transportation, Voltage Conversion, Water Pump
  • Number of Poles: 2
  • Contact Material: Brass
  • Features: Heavy Duty
  • Size: BEM-H180Z

    Description

    Industrial Grade Single-phase Solid State Relays Module DC-AC
    SSR-100DA~ 500DA
    Product Description:
    Product Name: Industry Solid State Relay
    Product model: 80/100/120/150/180/200/250/300/350/400/450/500 DA optional
    Current: DC controlled AC
    Control voltage: 4~32VDC
    Load voltage: 30~480VDC
    On-off time: ≤10MS
    Ambient temperature: -30°C ~ +70°C
    Product features: strong anti-interference, convenient installation, silent, no contact, no spark, etc.
    Isolation voltage>2500VAC
    Three Misunderstandings in the Selection of Solid State Relays
    Misunderstanding 1: Solid state relay is a complete AC contactor;
    Answer: a: Solid state relays have no auxiliary contacts
    b: The solid-state relay will generate heat when it is working, and it must be used with a radiator. For high power, fan cooling or water cooling is required.
    Misunderstanding 2: The identification current of the solid state relay is the actual working current;
    Answer:
    a: The solid state relay needs to leave a margin when selecting the model
    b: Option formula
    ①Pure resistance is 2.5 times, actual current (A) × 2.5 = solid state relay current (A)
    ②7 times of inductive load, actual current (A) × 7 = solid state relay current (A)
    For example (resistance): the customer needs 50A, the formula is: 50*2.5=125A, it is recommended to buy 150A or above.
    For example (perceptual): the customer needs 50A, the formula is: 50*7=350A, it is recommended to buy 350A or above.
    Misunderstanding 3: The safe service life is 6 years, that is, the product will be automatically damaged after 6 years;
    answer:
    a. The service life of 6 years is the safe replacement cycle established by the engineering department
    b. After 6 years, the product is still intact, but the safety cycle has passed.
    Reminder:
    1. The solid-state relay generates a lot of heat. When the load current is greater than 10A, it needs to be used with a radiator. Apply thermal grease between the solid-state relay base plate and the radiator, and add a fan for forced cooling above 60A.
    2. In the closed state, there is an off-state leakage current ≤ 5mA, which is not applicable to special scenarios. Please purchase with caution.
    Package include:
    According to your choice!
    If you need to purchase more than the inventory, please contact customer service to buy!